Test method | Required value | Average values | ||
Water absorption | ASTM C373 | ≤ 0.5% | 0.1% (Value referred to ceramic material only) | |
Deep abrasion resistance | ASTM C1243 | ≤ 175 mm3 | CONFORMS | |
Linear thermal expansion | ASTM C372 | NO PROVISION | α ≤ 8 x 10-6 °C-1 α ≤ 4.4 x 10-6 °F-1 |
|
Stain resistance | ASTM C1378 | As indicated by manufacturer | A RESISTANT | |
Chemical resistance | ASTM C650 | As indicated by manufacturer | A RESISTANT (Excluding hydrofluoridric acid and its derivatives) |
|
Frost resistance | ASTM C1026 | As indicated by manufacturer | RESISTANT | |
Slip resistance | DIN 51130 BCR-TORTUS |
- |
R9 > 0,40 |
|
Shade variation | ANSI A137.1 | As indicated by manufacturer | V2 SLIGHT VARIATION | |
Flame spread Fire reaction |
ASTM E84 EN 9239-1 - EN 13823 |
- | Class A Classe A1 FL / Classe A2 FL - s1 (ZERO.3 PLUS) Classe A1 / Classe A2 - s1, d0 (ZERO.3 PLUS) |
|
Thermal conductivity | EN 12524 | - | λ = 1,3 W/m °K / 0.7 BTU/ft h °F | |
Thermal shock resistance | ISO 10545-9 | No alterations | Resistant | |
Breaking strenght Modulus of rupture |
ASTM C1505 | ≥ 85 lbf - |
≥ 85 lbf ≥ 6000 PSI |